Noise generated by HVAC, Chiller, Evaporator and Air Conditioning
Noise generated by rooftop and ground-level HVAC equipment - chillers, boilers, air handlers, etc. -- is fast becoming one of the most contentious environmental problems in urban areas worldwide. As urban noise collides with residential sprawl, residents and communities are demanding better noise abatement treatments for this type of equipment.

Reflective sound enclosure and architectural screens like concrete or brick simply redirect unwanted sound waves, and can actually increase noise via unintentional reflected or bounced sound waves.

Absorptive noise barrier walls and sound baffles actually absorb the unwanted sound waves and significantly reduce overall noise, minimizing the risk of unintentional reflected noise. Therefore they are the single most effective tool for providing unwanted noise reduction from HVAC, chillers and related sources.

The PI noise control Panel System actually "kills” the sound waves that hit it and effectively provides noise reduction, therefore it is the perfect solution to HVAC Noise, Chiller Noise, and Cooling Tower Noise; or to virtually any industrial noise application. The noise absorptive panels are easy to install and maintenance free. Since the System has such a high absorptive value the possibility of reflective noise is eliminated.
Acoustical Performance
Octave Band # 1 2 3 4 5 6 7 8 NRC STC
Octave Band Hz 63 125 250 500 1K 2K 4K 8K NRC STC
Transmission Loss 18 21 27 37 48 55 55 54 33
Absorption Coefficients 0.78 0.94 0.99 0.99 0.92 0.9 0.95
STC: Sound Transmission Class (Overall Rating)      NRC: Noise Reduction Coefficient
 
Distinguishing Features of the Barrier Wall System
The Barrier Walls system is simply thx most effective noise abatement solution available for this very demanding application – outperforming and outlasting all other noise reduction products in its class. Plus, it is an aesthetically pleasing HVAC sound baffle with the added benefit of noise reduction.
Lightweight Non-Corrosive and non-conductive Win load tested to
Easy to assemble and disassemble 200 km/h
Modular Design Strong and durable
Fully Absorptive
Physical Dimensions
Length 2200 mm
Depth 100 mm
Height 530 mm
Area 1.16 m2
Weight 13 Kg / m2
Panel Weight 15 Kg
Column Center Distance 2220 mm
Construction of Acoustical Panels
The panels can be manufactured from aluminum or GI sheets to form a box-like modular unit. They can be produced in two different thicknesses according to required damping grade. Usually they are made in 50 or 100 mm thick pannel element. The exterior sheet is usually manufactured from a minimum of 1.2 mm galvanized steel or Aluminum sheets. The interior sheet shall be a minimum of 0.7 mm galvanized steel. The interior sheet shall be perforated with 3 mm diameter holes on 5 mm centers in all areas to provide min 40% open area. Panels are respectively insulated with 50 or 100 thick 40 Kg/m3 fiberglass.

Internal Acoustic Media (Fill)
40 Kg per cubic meter density of rock wool packed under not less than 5% compression to eliminate voids. Material is moisture and corrosive resistant, non- combustible, smokeless, odorless, and vermin proof. The mineral fiber fits into the panel cavity against the perforated face.
Top Cap
A top cap is required to protect the top row of panels from weather exposure. The channel is positioned with legs down. A special designed top cap channel section is usually formed from the same panel material. This top cap channel is bolted to the top of every panel.
Doors
Single swung metal acoustic doors complete with hardware and locks are available for locations where outside access is required. Single & Double size gates can also be supplied for the barrier wall system.
Erection and Assembly
The panels are stacked on top of each other like building blocks until desired height is attained, the wall is assembled by manually inserting panels to interlock with adjacent columns to form a self supporting structure. It is important that the tongue groove joints between the panels are clean fitted and the panels are level with each other.
Powder Coating
The noise Barrier Wall panels are powder coated. PI System offers powder coating to standard RAL- colors. Customized* colors can be produced on extra cost to match buildings or equipment if desired. The powder coated panels will retain original color for many years with minimum fading.
Note
Using of Acoustical Louvers in wall barrier applications like it has been proposed by others is not applicable and it would be very expensive solution. Changing the louver design in order to reduce the cost will leak to mal function of the louver as it has been scientifically designed for sound travel and appropriate noise reduction. The only internationally applied solutions for these applications are the proposed wall barrier system ax described in this document. Below we are listing some examples from different similar applications.
Examples for Chiller Noise Barier Walls